Cooling and heating faults
Hisense Compressor Not Starting, Why Only the Indoor Fan Runs
When the Hisense compressor is not starting, the indoor fan keeps blowing but the air never gets cold or warm. This guide explains why that happens, which codes often appear and what you can safely check.
The fan hums along, the louvre swings and air is definitely moving. Yet stand under the indoor unit and the airflow feels no different from the rest of the room. This is the classic sign of a Hisense compressor not starting. It is also one of the more common complaints owners raise on hot or cold days.
The compressor is the heart of the system. It lives in the outdoor unit and pumps refrigerant around the circuit so heat can be moved in or out of your home. If it does not start, the indoor fan can still run, but it simply recirculates room air. Sometimes the cause is a normal delay, and sometimes it is a part that needs replacing.
How do you know the compressor is not starting?
A few clues help you separate a compressor problem from other faults. First, the air from the indoor unit is roughly room temperature after several minutes in cool or heat mode. Second, the outdoor unit is either completely silent or only the outdoor fan is turning. Third, you may hear a click or a short hum from the outdoor unit, followed by quiet.
In addition, many Hisense systems show a fault code or flash a light pattern in this situation. That happens when the compressor fails to start or protection stops it. Note what you see before switching anything off, because the display may clear after a reset.
Normal reasons the compressor waits
Not every delay is a fault. Hisense units follow built in routines that pause the compressor on purpose. So it is worth ruling these out before worrying.
Three minute restart protection
Hisense manuals describe a protection delay of about three minutes after the unit stops or the mode changes. During this window the compressor will not restart, even if the indoor fan runs. This protects the compressor from starting against high pressure.
Room already at the set temperature
Inverter systems slow down or pause the compressor once the room reaches the target. For example, say the remote is set to 25 degrees in cool mode and the room is already at 24. In that case the compressor may stay off. Lower the set point by a few degrees and wait a few minutes.
Wrong mode selected
In fan only mode the compressor never runs. Dry mode also runs it gently and intermittently. Check the remote screen shows cool or heat, depending on what you need.
Defrost and warm up in heat mode
During cold weather the system may pause heating to clear ice from the outdoor coil. In that phase the fans stop for a short period and the running light may flash. Likewise, when heating first starts there is a short warm up with no airflow. Both are normal and resolve on their own.
Why is my Hisense compressor not starting?
Once normal delays are ruled out, the cause is usually electrical, a protection trip or a mechanical issue. Here are the common reasons, roughly from the simplest to the most serious.
- The outdoor unit has no power because a separate breaker has tripped or the isolator is off.
- The outdoor coil is blocked by dust, leaves or lint, so the system overheats and protects itself.
- Dirty indoor filters reduce airflow and trigger anti freeze or overload protection.
- The supply voltage is too high or too low, so the outdoor board refuses to start the compressor.
- A fault in the communication cable or boards stops the indoor unit telling the outdoor unit to run.
- A sensor gives a false reading, and the control board blocks the start for safety.
- The inverter power module on the outdoor board has failed or is in protection.
- Low refrigerant, often from a leak, causes the system to shut the compressor down.
- The compressor itself is seized, worn or has a winding fault.
Fault codes linked to compressor start problems
Codes give a technician a head start. The meanings below are the typical ones on many Hisense wall split inverters. That said, they vary by model range and control board, so confirm them in the manual for your model number.
- Code 18 commonly means the compressor has failed to start.
- Code 5 often relates to IPM protection, the inverter power module on the outdoor board. It may be a normal protection trip, a faulty module or a compressor problem.
- Code 6 typically points to over or under voltage protection.
- Codes 8 and 9 usually relate to current overload and maximum current protection.
- Code 13 often means the compressor discharge temperature is too high, which can follow a dirty coil, a refrigerant issue or a faulty sensor.
- Next, code 15 commonly indicates compressor housing overheat protection.
- Code 36 typically means a communication fault between the indoor and outdoor units.
- EC on some models points to refrigerant leak detection or low refrigerant protection.
If the running light flashes rather than showing a number, count the flashes between pauses. Repeat the count a couple of times to be sure, then write it down.
Sounds and signs worth noting
What you hear from outside can be just as useful as a code. A loud hum that stops after a few seconds may suggest the compressor is trying and failing to turn. Meanwhile, repeated clicking every few minutes often means the system keeps attempting a start and then giving up.
Other signs matter too. A breaker that trips the moment the compressor tries to start points towards an electrical fault rather than a setting. Ice on the pipes at the outdoor unit in cool mode, or oily marks around pipe joints, may hint at a refrigerant problem. Finally, a burnt smell near the outdoor unit means switch off at the isolator and leave the system off until it is inspected.
Jot these observations down alongside the code. Together they help a technician work out whether to focus on power, controls or the refrigerant circuit.
Safe checks before you call
A few simple steps can sometimes get things moving. Each one stays on the outside of the equipment, so they are safe for owners.
- Check the remote is in cool or heat mode and set a few degrees below or above the room temperature.
- Wait at least five minutes after any change, so the three minute protection delay has passed.
- Look at the switchboard for a tripped breaker, and check the isolator near the outdoor unit is on.
- Switch the system off at the isolator, wait about five minutes, then switch it back on and try again.
- With power off, clean the indoor filters and let them dry before refitting.
- Clear leaves, grass and stored items from around the outdoor unit so air can flow freely.
- Write down any code or flash pattern, and find the model number on the rating sticker of the indoor unit.
If the compressor starts after these checks and keeps running, keep an eye on it over the next few days. However, if it fails again, or the breaker trips, stop resetting it and arrange a service.
A compressor that will not start involves high voltage parts and a sealed refrigerant circuit. Do not open the outdoor unit, touch any capacitor, or try to add gas. Capacitors can hold a dangerous charge even with power off, and refrigerant work in Australia must be done by a licensed technician.
Heatwaves, cold snaps and operating limits
Australian weather can push systems hard. On a very hot afternoon in Perth, Adelaide or inland NSW, an outdoor unit sitting in full sun may reach its upper operating limit. Then protection can stop the compressor until conditions ease. Similarly, on frosty mornings in Canberra or regional Victoria, heating may struggle near the lower limit.
In these cases the system is protecting itself rather than failing. Even so, a unit that trips often in normal weather deserves a closer look. Dirty coils, poor airflow around the outdoor unit and low refrigerant all make protection trips more likely.
What a technician will check
A qualified technician works through the system in a logical order. Typically they start by confirming the fault code history and the supply voltage at the outdoor unit. Next, they inspect the interconnecting cable, the boards and the sensors.
From there, they may test the compressor windings, the inverter module and any relays or capacitors used on your model. They will also check pressures and look for signs of a refrigerant leak if the symptoms suggest it. Then they can explain whether a part replacement, a clean or a leak repair makes sense.
Sometimes the news is not good. A compressor that has failed outright can be a major repair, and on an older system replacement of the unit may be worth considering. A good technician will set out the options honestly so you can decide.
Can low refrigerant stop the compressor?
Yes, on many models it can. When refrigerant is low, pressures and temperatures inside the system go outside normal limits. As a result, protection may stop the compressor or prevent it starting. Some Hisense models show EC in this situation.
Air conditioners are sealed systems, so low refrigerant almost always means a leak somewhere. Simply topping up is not a lasting fix. Instead, the leak needs to be found and repaired by a licensed technician before the system is recharged.
Warranty and older systems
For newer units, check the warranty first. Hisense states a 5 year parts and labour warranty on split systems sold in Australia, and the warranty card explains how to claim. While your system is covered, contact Hisense before booking anyone else, because unauthorised repairs may affect the warranty.
For systems outside that period, an independent technician can diagnose the fault and give you repair options. Having the model number and a note of any codes will help.
The main points
When only the indoor fan runs, the compressor in the outdoor unit is not doing its job. Start by ruling out normal delays, the wrong mode and a set point the room has already reached. Then check the breaker and isolator, clean the filters and clear the outdoor unit. Codes such as 18, 5, 6 and 36 often help identify the cause.
If your Hisense compressor is not starting after these checks, book a qualified technician on 03 7048 4120. Have the model number and any code ready so the visit is as useful as possible.
Frequently asked questions
Why is my Hisense indoor fan running but no cold air?
The most likely reason is that the compressor in the outdoor unit is not running. It may be waiting out a three minute protection delay, the room may already be at the set temperature, or there may be a fault. If the air stays at room temperature after five minutes, check for a code.
What does code 18 mean on a Hisense air conditioner?
On many Hisense wall split inverters, code 18 typically means the compressor failed to start. Causes can include a supply problem, a board fault or a compressor fault. Confirm the meaning in the manual for your model, then book a technician.
Can I reset my Hisense compressor myself?
You can switch the whole system off at the isolator or breaker, wait about five minutes and switch it back on. That sometimes clears a protection trip. Do not open the outdoor unit or touch any internal parts.
Why does my outdoor unit click but the compressor does not start?
A click can be a relay or contactor trying to start the compressor. If the compressor then stays silent, there may be a voltage problem, a failed component or a compressor fault. This needs testing by a licensed technician.
Does hot weather stop the compressor from starting?
Very high outdoor temperatures can push the system past its operating limits, and protection may stop the compressor. Shade around the outdoor unit and a clean coil help. If it happens in normal weather, book a service.
Can dirty filters stop my compressor running?
They can contribute. Clogged filters reduce airflow, which can trigger anti freeze or overload protection and stop the compressor. Cleaning the filters is a safe first step for any owner.
Is a compressor fault worth repairing?
It depends on the age and condition of the system and the exact fault. Some problems, such as a failed board or sensor, are relatively simple, while a seized compressor is a major repair. A technician can explain the options after diagnosis.
Will Hisense cover a compressor that will not start?
If your system is within the warranty period, the fault may be covered depending on the cause and the terms. Hisense states a 5 year parts and labour warranty on split systems in Australia. Contact Hisense first and check your warranty card.
Need a hand with your Hisense air conditioner?
If a fault keeps returning after the safe owner checks, a qualified technician can test the unit properly and explain your options before any work starts.
Call 03 7048 4120Booked service across VIC, NSW, QLD, WA, SA and the ACTCall 03 7048 4120